Description
Constant temperature fluorescence detector is mainly used for constant temperature amplification and real-time fluorescence detection of samples. In conjunction with corresponding reagents, it can be used in food safety, aquaculture diseases, pet infectious diseases, plant diseases, scientific research and many other fields, such as the detection of food safety biological factors in the food industry chain, the detection of pathogenic microorganisms, the identification of genetically modified materials, the identification of adulteration and adulteration, etc.;It can be used for the detection of aquaculture diseases, such as the monitoring of epidemic pathogens, the control of breeding risk factors, quarantine of origin, seed quarantine, parental quarantine, etc.;It can also be used for pet infectious disease detection, helping pet doctors diagnose and treat diseases more effectively and accurately, saving detection time and inspection costs; its advantages are rapid detection, accurate detection, easy operation, on-site detection, and suitable for grassroots personnel use.The instrument can also be used in scientific research, universities, etc., for reagent development, target gene detection and other projects.
Independent and humanized operating system, the results can be directly interpreted through screen operation; The instrument can realize data storage, recall, result analysis and report, and can export experimental data by USB; reserve GPRS function, which can expand remote monitoring and data transmission functions.
Specifications
Model Technical parameters | CA-FD-CT-1600/FD-CT-1600D | |
Sample tray |
Sample size | 0.2mL–16 holes (8-strip tubes are available) |
Reaction system | 15-150μL (recommended 25-30μL) | |
Applicable dyes | FAM/ROX etc. | |
Temperature control |
Temperature range (℃) | Room temperature~99℃ |
Maximum heating rate (℃) | 2℃/s | |
Maximum cooling rate (℃) | 2℃/s | |
Temperature uniformity (℃) | ±0.15℃ | |
Temperature accuracy/temperature control accuracy (℃) | ±0.1℃ / 0.1℃ | |
Hot lid function | Yes, the temperature is adjustable | |
Light path system |
Channel | Single/dual channel optional |
Excitation wavelength | 470nm/570nm | |
Detection wavelength | 525nm/625nm | |
Excitation light source/detection method | Cold light source LED/real-time fluorescent signal detection | |
Function
|
Data analysis | According to the tested samples, direct analysis to determine positive or negative |
Result display method | 1. Negative/positive; 2. Peak starting time; 3. Melting Tm value | |
Interpretation method | 1. Construction of the amplification curve to judge; 2. Automatic judgment of the instrument | |
Display screen | 7-inch touch screen | |
Controlling software | Instrument software | |
Power supply | Power supply | AC100-240V DC15V6A |
Size and weight | Size (W*D*H) | 195*275*112mm |
Weight | 4.5kg |
Reviews