SP-IAA1800H atomic absorption spectrometer is widely used in scientific research, quality inspection, disease control, environmental protection, metallurgy, agriculture, forestry, chemical industry and other industries, innovative software and hardware design to ensure the accuracy of the sample analysis, safety, ease of use, simple and convenient instrument maintenance.
Features
- High precision fully automatic optical system
Large area grate with 1800 lines/mm dispersion rate, novel self-collimating monochromator, all lense are Shi Ying coated, wide detection range and optical stability ensure that accuracy of analysis. Automatic 6 lamp holder equipped with 6 independent lamp power supply, can respectively preheating.
- Polymer atomizing chamber
High-molecular material anti-corrosion atomization chamber, acid and alkali resistant, including hydrofluoric acid, whether organic or inorganic solution can get better sensitivity and stability.
- Titanium burner
Titanium burner, optional 50mm and 100mm burner, air cooling pre mixed type, corrosion resistance, high salt resistance, greatly improve the efficiency of the flame and flame analysis accuracy.
- Fully automated analysis
It can automatically complete safe ignition, extinguishing and switching, with reliable structure and low failure rate, thus ensuring the sensitivity and repeatability of the flame method;The light source system automatically switches the six-lamp-position platform, can directly use the high-performance hollow cathode lamp, improves the sensitivity of flame analysis, automatically adjusts the power supply parameters and the beam position, and fully automatically scans and searches for the wave crest.
- Graphite furnace temperature control
Double temperature control of internal and external air, 20-order linear or nonlinear temperature rise, to ensure that the elements to be tested have good sensitivity; Enrichment and concentration were carried out for 20 times in the furnace. The inner wall temperature of the graphite tube was monitored by longitudinal light control, and the maximum temperature could be increased to 3000 C/s.
- High technology index
The element test sensitivity of SP-IAA1800H atomic absorption spectrometer reaches the advanced level in the industry, with the sensitivity ≤0.015 µ g/mL/1%; Baseline drift less than 0.003Abs/30m with better stability than 0.005Abs/4h.
- Background correction system
The deuterium hollow cathode lamp and the self-absorption button background are adopted for background correction, so that the interference of molecular absorption in the determination of low content is eliminated, the emission noise of the deuterium lamp is reduced, the service life is prolonged, and the deuterium hollow cathode lamp has good stability. When the background signal of deuterium lamp is 1A, the background subtraction ability is > 50 times.
- Intelligent analysis
Intelligence is very strong, humanized design, flame and graphite furnace atomization device automatic switching, graphite furnace atomization device automatic optimization, automatic setting to adjust the flame height, automatic ignition, automatic optimization of horizontal position, the system automatically set the gas flow. In case of power outage, misoperation, acetylene leakage, etc., the system will automatically start the safety protection function;
- Automatic sampler
Integrated with graphite furnace, high-precision injector was used, and the minimum volume of sample could be 0.5 µL. The intelligent online dilution and concentration function was realized.
Specifications
Main engine
Model | SP-IAA1800H |
Light source | Single-element or multi-element hollow cathode lamp |
Lamp holder | Automatic switching of six-lamp platform and full-automatic collimation |
Lamp current | Pulse power supply |
Optical system | Large area 1800 /mm reticle grating, fully enclosed optical system |
Wavelength range | 190-900nm, automatic peak finding, one-button optical optimization |
Wavelength accuracy | ≤0.15nm |
Wavelength repeatability | ±0.1nm |
Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0nm Auto Set |
Baseline drift | Static ≤ 0.002 A/30 min, dynamic ≤ 0.005 A/30 min |
Absorbance range | 0-4A |
Detector | imported photomultiplier tube |
Flame system
Burner head | All titanium burner head, 50mm or 100mm universal burner head |
Atomizing chamber | Macromolecule anti-explosion and anti-corrosion atomizing chamber |
Nebulizer | High-efficiency glass nebulizer, can also be customized |
Ignition mode | Microcomputer control, automatic ignition |
Gas control | Manual operation |
Characteristic concentration | 0.015µg/mL/1%(Cu) |
Detection limit | 0.002µg/mL(Cu) |
Precision | RSD≤0.5% |
Safety | Multiple protection measures such as gas leakage alarm, automatic protection against tempering, and automatic power failure in case of abnormality |
Graphite furnace system
Heating mode | Longitudinal heating |
Temperature control mode | Longitudinal optical temperature control monitors the inner wall temperature of the graphite tube |
Temperature range | RT to 3000 c |
Program temperature control | Automatic temperature control up to 20 stages, enrichment and concentration in the furnace up to 20 times |
Characteristic quantity | 0.5 × 10–12g (CD) |
Detection limit | 0.4 × 10–12g (CD) |
Precision | RSD≤3% |
Cooling water | Optional cooling water circulation system |
Safety | Graphite tube damage, water flow, air pressure alarm; Water temperature overheat protection |
Graphite furnace autosampler (optional)
Sample tray | 130-position sample cup, 6-position reagent cup |
Injection volume | 0.01-100µl |
Minimum increment | 0.01µl |
Injection volume repeatability | 1% |
Duplicate injections | up to 99 |
Wash container volume | 500mL |
Background correction
Deuterium lamp background correction | 1A background can be corrected |
Self-priming background correction | 1A background can be corrected |
Data processing
Measurement methods | Flame method, graphite furnace method, hydride generation-atomic absorption method |
Calculation methods of concentration | Standard curve method (cubic curve), automatic fitting, and standard addition method |
Repeat measurement times | 1–99 times, calculate the average value, and give the standard deviation and relative standard deviation |
Result printing | Parameter printing, data result printing, graphic printing, and word and excel documents can be exported |