Description
pH
• Multi parameter water quality meter is equipped with a 3.5 inches backlit LCD display
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers
• Automatic electrode diagnosis shows the pH slope and offset
ORP
• 1 point offset calibration allows adjusting the displayed value to a known standard
• Relative and absolute millivolt modes ensure the reliable ORP measurements
Ion Concentration
• 2 to 5 points calibration, including the 8 concentration points can be selected
• Direct ion concentration readout simplifies the measurement process
• Automatic electrode diagnosis shows the calibration points and slopes
• Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency
Conductivity/TDS/Salinity/Resistivity
• 1 to 5 points calibration with automatic recognition for conductivity standards
• Selectable cell constant, reference temperature, TDS factor, linear and pure water
compensations, seawater and practical salinity measurement modes
• Automatic electrode diagnosis shows the calibration points and factors
Dissolved Oxygen
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution
• Salinity and barometric pressure compensations eliminate the measurement error
General Features
• Automatic temperature compensation ensures accurate readings over the entire range
• Auto-Read function senses and locks the measurement endpoint
• Calibration due alarm prompts user to calibrate the meter regularly
• Auto-Power Off effectively conserves battery life
• Setup menu allows setting the number of calibration points,resolution,stability criteria,
temperature unit, date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults
• Expanded memory stores or recalls up to 500 data sets
• USB communication interface is easy to transfer data to PC
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that using
Measurement Parameters
• BEP-M900P: pH, mV, relative mV, ion concentration, conductivity, TDS,
salinity, resistivity, DO, temperature
• BEP-M901P: pH, mV, conductivity, TDS, temperature
• BEP-M902P: pH, mV, relative mV,conductivity, TDS,salinity, resistivity,
Temperature
• BEP-M903P: pH, mV, relative mV, DO, temperature
• BEP-M904P: Conductivity, TDS, salinity, resistivity, DO, temperature
Specifications
Model | CA-BEP-M900P | CA-BEP-M901P | ||
pH | Range | -2.000-20.000pH | • | • |
Resolution | 0001,0.01,0.1pH, selectable | • | • | |
Accuracy | 0.002pH | • | • | |
Calibration Points | 1 to 5 points | • | • | |
pHBuffer Options | USA, NIST, DIN, 2 custom buffers | • | • | |
ORP | Range | ±1999.9mV | • | • |
Resolution | 0.1, 1mV, selectable | • | • | |
Accuracy | ±0.2mV | • | • | |
Calibration Points | 1 point | • | – | |
Ion | Range | 0.001~19999 (depending on the range of ISE) | • | – |
Resolution | 0.001, 0.01, 0.1, 1 | • | – | |
Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) | • | – | |
Measurement Units | ppm, mg/L, mol/L, mmol/L | • | – | |
Calibration Paints | 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) | • | – | |
Conductivity | Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | • | • |
Resolution | 0001,0.01,0.1,1 | • | • | |
Accuracy | ±0.5% F.S. | • | • | |
Calibration Paints | 1 to 5 points | • | • | |
Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | • | • | |
Temperature Coefficient | Linear(0.0-10.0%/°C | • | • | |
).pure water | ||||
Reference Temperature | 20/25°C | • | • | |
Cell Constant | K=0.1, 1, 10 or custom | • | • | |
TDS | Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt | • | • |
Resolution | 001,0.1,1 | • | • | |
Accuracy | ±1% F.S. | • | • | |
TDS Factor | 0.1~1.0 (default 0.5) | • | • | |
Salinity | Range | 0.00~42.00psu, 0.00~80.00ppt | • | – |
Resolution | 0.01 | • | – | |
Accuracy | ±1% F.S. | • | – | |
Resistivity | Range | 0.00~20.00MΩ | • | – |
Resolution | 0.01 | • | – | |
Accuracy | ±1% F.S. | • | – | |
DO | Range | 0.00~20.00mg/L, 0.0~200.0% saturation | • | – |
Resolution | 001mg/L,0.1% | • | – | |
Accuracy | ±0.2mg/L, ±2.0% | • | – | |
Calibration Points | 1 or 2 points | • | – | |
Barometric Pressure Correction | 60.0~112.5kPa/450~850mmHg, manual | • | – | |
Salinity Correction | 0.0~50.0g/L, manual | • | – | |
General Spec. | Temperature Compensation | 0~100°C/32~212°F, manual or automatic | • | • |
Memory | 500 data sets, USB communication interface | • | • | |
Power Requirements | 3× 1.5V AA batteries or DC5V power adapter | • | • | |
Dimensions and Weight | W*D*H170× 85 ×30mm, 300g | • | • | |
Package Dimension and
G.W. |
W*D*H440*320*120mm
2.2kg |
• | • |